ilpa100vu series 100w water - proof constant voltage led driver C wide input voltage 90 to 305vac, 47 to 63hz C constant output voltage available from 12vdc thru 105vdc C over voltage, over current, short circuit, lighting, and over temperature protection C high efficiency (up to 93%) C active power factor correction (pfc) (99% typical) C ip67 waterproof rating, metal housing C comply with ul8750 & en61347 safety regulation (pending) 3 year warranty approvals: single output part number output voltage max. output current efficiency (220vac, full load) over voltage protection min / typ / max max. output power ilpa100vu - s012st 12 vdc 8.33 a 91% 14v / 15v / 16v 100w ilpa100vu - s024st 24 vdc 4.05a 93% 27v / 30v / 34v 100w ilpa100vu - s036st 36 vdc 2.75 a 93% 40v / 47v / 50v 100w ilpa100vu - s042st 42 vdc 2.25 a 93% 47v / 52v / 57v 100w ilpa100vu - s048st 48 vdc 1.95 a 92% 54v / 59v / 63v 100w ilpa100vu - s054st 54 vdc 1.75 a 93% 60v / 68v / 75v 100w ilpa100vu - s081st 81 vdc 1.23 a 93% 91v / 95v / 100v 100w ilpa100vu - s105st 105 vdc 0.95 a 93% 120v / 125v / 140v 100w electrical characteristics parameter test conditions min. typ. max. unit input voltage operating voltage 90 305 vac input frequency 47 63 hz output power range vin=90 to 264vac 0 100 w input current (low line) io=full load, vin=115vac 1.20 a input current (high line) io=full load, vin=230vac 0.60 a high line inrush current io=full load, 25c, cool start, vin=230vac 65 a power factor correction vin=110vac 99 % power factor correction vin=220vac 96 % efficiency io=full load, vin=230vac 93 % no - load power consumption no load, vin=230vac 1.5 w line regulation io=full load 1 % load regulation vin=230vac 2 % over voltage protection latch mode. the power unit shall return to normal operation only after the power is turn - on again. (please refer to output table.) over current protection 110 135 180 % io over temperature protection 110 c short circuit protection no damage shall occur when any output operating in a short circuit condition. the power supply shall be self - recovery when the fault condition is removed. output overshoot / undershoot when power on or off 10 % start up time io=full load, vin=100vac 3 s ripple & noise (peak to peak) measured by 20 mhz bandwidth oscilloscope and the output paralleled a 0.1 uf ceramic capacitor and a 10 uf electrolytic capacitor. 2 % vo
conditions parameter test conditions min. typ. max. unit operating temperature - 35 70 c storage temperature - 40 85 c relative humidity 5 95 % operation temperature at 25c, calculated per mil - hdbk - 217f 0.439m hours life time at 25c ambient temperature 0.193m hours no output power derating from - 35c to 60c approvals and compliance parameter standards emi en55015 ems en61000 - 3 - 2, en61000 - 3 - 3, en61000 - 4 - 2, en61000 - 4.3, , en61000 - 4 - 4, , en61000 - 4 - 5, en61000 - 4 - 6, en61000 - 4 - 8, en61000 - 4 - 1 - 1, en61547 safety ul/c - ul, t - mark, ce ul8750 compliant to ul1310 class 2, ul1012, ul935, csa - c22.2 no. 0, csa - c22.2 no. 107.1, csa - c22.2 no.250.0, en61347 - 1,en61347 - 2 - 13 waterproof ip67 rating mechanical parameter specification dimension, net weight 184x67.5x37mm (7.24x2.66x1.46 inches), 950g approx. input electric wire 650mm, black(acl), white(acn), green(gnd) output electric wire 220mm, red(v+), black(v - )
|